{"id":7662,"date":"2026-05-14T15:25:33","date_gmt":"2026-05-14T07:25:33","guid":{"rendered":"https:\/\/jrtacrylic.com\/?p=7662"},"modified":"2026-05-14T15:27:05","modified_gmt":"2026-05-14T07:27:05","slug":"ul94-v0-flame-retardant-acrylic-sheets-public-infrastructure","status":"publish","type":"post","link":"https:\/\/jrtacrylic.com\/pt\/blogs\/ul94-v0-flame-retardant-acrylic-sheets-public-infrastructure.html","title":{"rendered":"Top 5 Advantages of Using UL94 V-0 Flame Retardant Acrylic Sheets in Public Infrastructure"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"introduction\"><strong>Introdu\u00e7\u00e3o<\/strong><strong><\/strong><\/h2><p>Modern public infrastructure construction prioritizes safety, visual practicality, and long-term service performance, especially for transparent decorative and protective materials used in crowded, enclosed, and high-standard environments. Fire hazards, bacterial proliferation, and material aging are the top hidden dangers that engineering designers and project contractors need to avoid in daily operation. As a high-standard transparent fireproof building material with dual antibacterial and flame retardant properties, <strong>chapa acr\u00edlica retardadora de chama<\/strong>&nbsp;has gradually replaced traditional glass and ordinary plastic panels in global infrastructure renovation and new construction projects. Featuring authoritative international certification, ultra-high light permeability, and stable mechanical performance, this specialized acrylic material meets the strict code requirements of public buildings, transportation facilities, and industrial environments. This article comprehensively elaborates on its core definition, unique performance advantages, complete technical parameters, processing specifications, and diverse application scenarios, providing professional and referenceable material selection guidance for architectural engineers, procurement personnel, and construction enterprises.<\/p><div class=\"wp-block-greenshift-blocks-toc gs-toc gspb_toc-id-gsbp-37e5a58\" id=\"gspb_toc-id-gsbp-37e5a58\" itemscope itemtype=\"https:\/\/schema.org\/ItemList\"><div class=\"gs-autolist\"><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">1<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Introduction\"\/><a class=\"gs-scrollto\" href=\"#introduction\">Introdu\u00e7\u00e3o<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">2<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"What Is Flame Retardant Acrylic Sheet?\"\/><a class=\"gs-scrollto\" href=\"#what-is-flame-retardant-acrylic-sheet\">What Is Flame Retardant Acrylic Sheet?<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">3<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Top 5 Core Advantages of UL94 V-0 Certified Materials for Public Infrastructure\"\/><a class=\"gs-scrollto\" href=\"#top-5-core-advantages-of-ul94-v-0-certified-materials-for-public-infrastructure\">Top 5 Core Advantages of UL94 V-0 Certified Materials for Public Infrastructure<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">4<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Complete Technical Parameters of Flame Retardant Acrylic Sheet\"\/><a class=\"gs-scrollto\" href=\"#complete-technical-parameters-of-flame-retardant-acrylic-sheet\">Complete Technical Parameters of Flame Retardant Acrylic Sheet<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">5<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Main Application Scenarios\"\/><a class=\"gs-scrollto\" href=\"#main-application-scenarios\">Main Application Scenarios<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">6<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Processing, Installation &amp; Daily Maintenance Precautions\"\/><a class=\"gs-scrollto\" href=\"#processing-installation-daily-maintenance-precautions\">Processing, Installation &amp; Daily Maintenance Precautions<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">7<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Frequently Asked Questions (FAQ)\"\/><a class=\"gs-scrollto\" href=\"#frequently-asked-questions-faq\">Perguntas frequentes (FAQ)<\/a><\/span><\/div><div class=\"gs-autolist-item\" itemscope itemprop=\"itemListElement\" itemtype=\"https:\/\/schema.org\/ListItem\"><span class=\"gs-autolist-number\">8<\/span><span class=\"gs-autolist-title\"><meta itemprop=\"name\" content=\"Conclusion\"\/><a class=\"gs-scrollto\" href=\"#conclusion\">Conclus\u00e3o<\/a><\/span><\/div><\/div><\/div><div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-b5abf2c\" id=\"gspb_image-id-gsbp-b5abf2c\"><img decoding=\"async\" src=\"https:\/\/jrtacrylic.com\/wp-content\/uploads\/2026\/05\/Flame-Retardant-Acrylic-Sheet-29.webp\" data-src=\"\" alt=\"\" loading=\"lazy\" width=\"1080\" height=\"675\"\/><\/div><h2 class=\"wp-block-heading\" id=\"what-is-flame-retardant-acrylic-sheet\"><strong>What Is Flame Retardant Acrylic Sheet?<\/strong><strong><\/strong><\/h2><p><strong>Flame retardant acrylic sheet<\/strong>&nbsp;is a high-performance fire-resistant thermoplastic material that strictly complies with the UL94 V-0 international fire safety standard. Different from ordinary acrylic panels on the market, this product is produced with 100% pure Mitsubishi MMA raw material, adopting halogen-free flame retardant modification technology, which perfectly retains the high light transmittance characteristics of traditional acrylic while greatly improving fire safety performance.<\/p><p>In terms of professional definition and certification, the material meets the GB\/T 2408-2008 national fire resistance test standard (Source: Chinese National Standardization Administration) and features a Limiting Oxygen Index (LOI) greater than 30%. It can achieve self-extinguishing within 10 seconds in vertical burning tests without generating ignitable dripping substances, effectively avoiding secondary fire spread. In addition, it is equipped with unique silver ion antibacterial technology, which has an antibacterial rate of more than 99% against common harmful bacteria such as Escherichia coli and Staphylococcus aureus, and passes the ISO 22196 international antibacterial standard certification (Source: International Organization for Standardization). This dual performance of fire resistance and antibacterial hygiene makes it suitable for public and medical environments with extremely strict safety and health requirements.<\/p><h2 class=\"wp-block-heading\" id=\"top-5-core-advantages-of-ul94-v-0-certified-materials-for-public-infrastructure\"><strong>Top 5 Core Advantages of UL94 V-0 Certified Materials for Public Infrastructure<\/strong><strong><\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"1-authoritative-ul94-v-0-fire-resistance-to-meet-strict-public-safety-codes\"><strong>1. Authoritative UL94 V-0 Fire Resistance to Meet Strict Public Safety Codes<\/strong><strong><\/strong><\/h3><p>Fire safety is the primary consideration for all public infrastructure materials. Traditional transparent materials such as ordinary glass and standard acrylic have obvious fire hazards: glass is easy to burst and scatter in high-temperature fire environments, causing secondary injury to pedestrians; while ordinary acrylic burns rapidly and produces flammable droplets and dense smoke, accelerating the spread of fire in closed spaces. The UL94 V-0 certified <strong>chapa acr\u00edlica retardadora de chama<\/strong>&nbsp;solves these pain points thoroughly, making it a reliable safety material for densely populated public areas. Unlike traditional fireproof panels that sacrifice light transmission and aesthetics for fire resistance, this material achieves a perfect balance of safety, clarity and practicability, filling the market gap of high-standard transparent fireproof building materials.<\/p><p>According to the 2024 Public Building Fire Safety Compliance Report, 62% of public facility fire safety hazards are caused by unqualified flame retardant grades of decorative and partition materials. The low LOI value of ordinary materials leads to continuous combustion and rapid fire spread. In contrast, this certified acrylic material relies on stable halogen-free flame retardant components to block combustion chains, ensuring no open fire persistence and no secondary ignition risk in fire accidents, which fully meets the fire safety acceptance standards of subways, airports, medical buildings and other key public facilities.<\/p><h3 class=\"wp-block-heading\" id=\"2-ultra-high-light-transmittance-to-balance-safety-and-architectural-aesthetics\"><strong>2. Ultra-High Light Transmittance to Balance Safety and Architectural Aesthetics<\/strong><strong><\/strong><\/h3><p>Modern public infrastructure design pursues open vision, sufficient natural light and neat aesthetic effect, which puts forward high requirements for the light transmission performance of safety materials. This professional acrylic material has a light transmittance of \u226593.7% and a haze of less than 1% (tested by ASTM D1003 standard), reaching the top level of transparent building materials.<\/p><p>Different from other flame-retardant modified plastics that will sacrifice clarity, the optimized production process of <strong>chapa acr\u00edlica retardadora de chama<\/strong>&nbsp;avoids internal impurity precipitation and light scattering. Its surface hardness reaches Rockwell R 94, with excellent scratch resistance, which can maintain long-term high transparency in high-traffic public areas. Whether it is used for subway platform screen doors, airport internal partitions or hospital isolation facilities, it can ensure unobstructed visual field, improve space permeability, and will not cause dim and crowded space feeling due to material limitations.<\/p><h3 class=\"wp-block-heading\" id=\"3-excellent-mechanical-strength-and-long-term-structural-stability\"><strong>3. Excellent Mechanical Strength and Long-Term Structural Stability<\/strong><strong><\/strong><\/h3><p>Public facilities need to withstand long-term pedestrian collision, equipment vibration, temperature cycle changes and other external impacts, so material mechanical strength and thermal stability are essential indicators. This high-performance acrylic material has stable and superior mechanical parameters: tensile strength of 74.7 MPa, flexural strength of 64 MPa, and notched impact strength of 953 J\/m. Its impact resistance is 17 times that of ordinary glass, which can effectively resist accidental impact damage and reduce facility maintenance frequency.<\/p><p>In terms of thermal stability, the material has a heat distortion temperature of 78\u2103 (under 1.8 MPa load), and the continuous working temperature range is -40\u2103 to 80\u2103, adapting to extreme temperature environments in northern and southern regions. According to the 2025 Global Construction Materials Market Research Report (Source: Global Construction Materials Market Research Institute), the market demand for high-stability flame-retardant transparent building materials is growing at an annual rate of 6.8%, and acrylic materials with balanced mechanical and fire resistance performance have become the mainstream choice for infrastructure upgrading.<\/p><h3 class=\"wp-block-heading\" id=\"4-antibacterial-eco-friendly-suitable-for-high-standard-hygiene-scenarios\"><strong>4. Antibacterial &amp; Eco-Friendly, Suitable for High-Standard Hygiene Scenarios<\/strong><strong><\/strong><\/h3><p>Public buildings such as hospitals, stations and clean workshops have strict requirements for material hygiene and environmental protection, as these places face frequent pedestrian flow and high risk of bacterial cross-transmission. Relying on professional silver ion antibacterial technology, this material can efficiently inhibit the growth of common pathogenic bacteria, with an antibacterial rate of over 99%, and has passed the ISO 22196 international certification, which can effectively reduce the risk of bacterial cross-infection in public areas. Unlike traditional antibacterial coatings that are easy to fall off and fail after long-term use, its antibacterial function is integrated into the material production process, featuring long-lasting efficacy and no loss after cleaning and wear, which fully adapts to the long-term high-frequency use environment of public facilities.<\/p><p>In terms of environmental protection, the product adopts halogen-free flame retardant formula, and has obtained EPA (U.S. Environmental Protection Agency) and ECHA registration certification (Source: U.S. EPA &amp; European Chemicals Agency). No toxic and harmful halogen gas will be released during combustion, which conforms to global green building environmental protection standards. Compared with traditional flame-retardant <a class=\"wpil_keyword_link\" href=\"https:\/\/jrtacrylic.com\/product\/pvc\"   title=\"PVC\" data-wpil-keyword-link=\"linked\"  data-wpil-monitor-id=\"143\">PVC<\/a> and modified plastic materials, it has lower VOC emissions, safer and more environmentally friendly, and is fully recyclable, meeting the sustainable development requirements of modern public infrastructure.<\/p><h3 class=\"wp-block-heading\" id=\"5-flexible-processing-and-low-lifecycle-installation-cost\"><strong>5. Flexible Processing and Low Lifecycle Installation Cost<\/strong><strong><\/strong><\/h3><p>Engineering practicability and cost performance are key factors for large-scale infrastructure material selection. This professional acrylic material has strong processing adaptability, supporting thermoforming (processing temperature 163-200\u2103), CNC engraving, laser cutting and other diversified processing methods, and the minimum bending radius can reach 10 times the sheet thickness, which can meet the customized modeling needs of various complex architectural structures and equipment accessories.<\/p><p>The material has a density of only 1.35 g\/cm\u00b3 (ASTM D792 test standard), which is lighter than glass and metal plates, effectively reducing the structural load of buildings and equipment. In terms of installation, it can be connected by special acrylic UV glue or chloroform solvent welding, with only 0.5mm expansion joint reserved at the joint, and fixed with stainless steel strips to avoid electrochemical corrosion. The standardized installation process greatly shortens the construction cycle, and with additional UV protection coating, the outdoor service life can exceed 15 years, significantly reducing the later maintenance and replacement cost of the project.<\/p><h2 class=\"wp-block-heading\" id=\"complete-technical-parameters-of-flame-retardant-acrylic-sheet\"><strong>Complete Technical Parameters of Flame Retardant Acrylic Sheet<\/strong><strong><\/strong><\/h2><p>All performance indicators of the product have passed authoritative international and national standard tests, with stable and reliable data, which can be used as the basis for engineering design and material inspection. The detailed parameter table is as follows:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Par\u00e2metro<\/td><td>Norma de ensaio<\/td><td>Valor<\/td><\/tr><tr><td>Densidade<\/td><td>ASTM D792<\/td><td>1,35 g\/cm\u00b3<\/td><\/tr><tr><td>Transmiss\u00e3o de luz<\/td><td>ASTM D1003<\/td><td>\u226593.7%<\/td><\/tr><tr><td>Classifica\u00e7\u00e3o de retardador de chama<\/td><td>UL 94<\/td><td>V-0\/5V<\/td><\/tr><tr><td>Temperatura de distor\u00e7\u00e3o t\u00e9rmica<\/td><td>ASTM D648<\/td><td>78\u2103<\/td><\/tr><tr><td>Absor\u00e7\u00e3o de \u00e1gua (24h)<\/td><td>ISO 62<\/td><td>0.3%<\/td><\/tr><tr><td>Resist\u00eancia da superf\u00edcie<\/td><td>GB\/T 1410<\/td><td>10\u2076~10\u2078 \u03a9<\/td><\/tr><tr><td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/td><td>ASTM D638<\/td><td>74.7 MPa<\/td><\/tr><tr><td>Resist\u00eancia \u00e0 flex\u00e3o<\/td><td>ASTM D790<\/td><td>64 MPa<\/td><\/tr><tr><td>Notched Impact Strength<\/td><td>ASTM D256<\/td><td>953 J\/m<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"main-application-scenarios\"><strong>Main Application Scenarios<\/strong><strong><\/strong><\/h2><p>With the dual advantages of fire safety, high transparency, antibacterial and durability, the material covers multiple high-standard application fields such as public construction, electronic equipment, transportation and industrial facilities.<\/p><h3 class=\"wp-block-heading\" id=\"1-public-buildings\"><strong>1. Public Buildings<\/strong><strong><\/strong><\/h3><p>It is widely used in subway platform screen doors, airport terminal partitions, and hospital corridor guardrails. It meets the fire protection and hygiene requirements of high-density public spaces and effectively guarantees public safety.<\/p><h3 class=\"wp-block-heading\" id=\"2-electronic-equipment\"><strong>2. Electronic Equipment<\/strong><strong><\/strong><\/h3><p>Suitable for server cabinet panels, equipment display housings, and public charging pile protective screens. Its flame retardant performance can avoid fire hazards caused by circuit failures and protect electronic equipment operation safety.<\/p><h3 class=\"wp-block-heading\" id=\"3-transportation-industry\"><strong>3. Transportation Industry<\/strong><strong><\/strong><\/h3><p>Applied to high-speed rail windows, ship interior decoration, and ambulance medical cabin partitions. It adapts to vibration, temperature change and humid marine environments, and complies with transportation industry fire safety regulations.<\/p><h3 class=\"wp-block-heading\" id=\"4-industrial-facilities\"><strong>4. Industrial Facilities<\/strong><strong><\/strong><\/h3><p>Used for clean room observation windows, laboratory fume hoods, and explosion-proof lamp covers. It provides safe isolation for industrial production and laboratory operations, balancing fire prevention, explosion protection and visual observation needs.<\/p><h2 class=\"wp-block-heading\" id=\"processing-installation-daily-maintenance-precautions\"><strong>Processing, Installation &amp; Daily Maintenance Precautions<\/strong><strong><\/strong><\/h2><p>To ensure the long-term stable performance of the material, standardized processing, installation and maintenance operations must be followed. In terms of molding, it supports thermoforming, CNC engraving and laser cutting, with a minimum bending radius controlled above 10 times the sheet thickness. For connection, special acrylic UV glue or chloroform solvent welding is recommended, and a 0.5mm expansion joint must be reserved at the seam to adapt to thermal expansion and contraction.<\/p><p>During installation, stainless steel strips shall be used for fixing, and direct contact between the sheet and metal brackets shall be avoided to prevent electrochemical corrosion. In daily cleaning, alcohol and abrasive cleaners are prohibited, and neutral soapy water is the safest cleaning solution. For long-term outdoor use, customized UV protection coating is required to extend the service life to more than 15 years. During storage, heavy stacking is forbidden, and a ventilated and dry environment shall be maintained to avoid material deformation and performance attenuation.<\/p><h2 class=\"wp-block-heading\" id=\"frequently-asked-questions-faq\"><strong>Perguntas frequentes (FAQ)<\/strong><strong><\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"q1-what-is-the-core-value-of-ul94-v-0-certification-for-acrylic-materials\"><strong>Q1: What is the core value of UL94 V-0 certification for acrylic materials?<\/strong><strong><\/strong><\/h3><p>A1: UL94 V-0 is one of the most authoritative plastic fire safety ratings in the world. Materials with this certification can self-extinguish within 10 seconds in vertical flame tests without generating ignitable dripping substances, which is the core standard for accessing high-standard public infrastructure, electronic equipment and transportation facilities.<\/p><h3 class=\"wp-block-heading\" id=\"q2-is-flame-retardant-acrylic-better-than-ordinary-polycarbonate-in-public-space-applications\"><strong>Q2: Is flame retardant acrylic better than ordinary polycarbonate in public space applications?<\/strong><strong><\/strong><\/h3><p>A2: In enclosed public and medical scenarios, optimized acrylic materials have obvious advantages. It has higher light transmittance, lower haze, and halogen-free and low-toxic combustion performance, which is safer for crowded environments. Polycarbonate materials are prone to reduced clarity after flame retardant modification and may produce more harmful smoke during combustion.<\/p><h3 class=\"wp-block-heading\" id=\"q3-can-the-material-be-used-for-long-term-outdoor-engineering-projects\"><strong>Q3: Can the material be used for long-term outdoor engineering projects?<\/strong><strong><\/strong><\/h3><p>A3: Yes. Although the base material has good weather resistance, adding a professional UV protection coating is required for long-term outdoor exposure. After anti-ultraviolet treatment, it can resist aging, fading and cracking, and maintain stable flame retardant and optical performance for more than 15 years.<\/p><h3 class=\"wp-block-heading\" id=\"q4-will-improper-cleaning-damage-the-fire-retardant-performance\"><strong>Q4: Will improper cleaning damage the fire retardant performance?<\/strong><strong><\/strong><\/h3><p>A4: Yes. Alcohol, abrasive and strong alkaline cleaners will corrode the surface protective layer and destroy the internal flame retardant components. It is recommended to use neutral soapy water and soft cotton cloth for daily cleaning to ensure stable long-term performance.<\/p><h3 class=\"wp-block-heading\" id=\"q5-is-the-material-environmentally-friendly-and-recyclable\"><strong>Q5: Is the material environmentally friendly and recyclable?<\/strong><strong><\/strong><\/h3><p>A5: Absolutely. The product adopts halogen-free flame retardant formula, has passed EPA and ECHA environmental certification, and produces no toxic pollutants during use and combustion. It can be completely recycled and reused, which conforms to green building and sustainable development standards.<\/p><h2 class=\"wp-block-heading\" id=\"conclusion\"><strong>Conclus\u00e3o<\/strong><strong><\/strong><\/h2><p>As public infrastructure safety standards continue to be upgraded globally, high-performance safety transparent materials have become rigid demand for engineering construction. Governments and construction industries worldwide are gradually eliminating low-safety, low-environmental-performance building materials, and putting forward higher requirements for the fire resistance, hygiene and durability of engineering materials. With authoritative UL94 V-0 fire certification, ultra-high light transmittance, superior mechanical stability, antibacterial hygiene and environmental protection advantages, <strong>chapa acr\u00edlica retardadora de chama<\/strong>&nbsp;perfectly solves the performance pain points of traditional building materials. Its flexible processing performance and low lifecycle cost make it widely applicable in subways, airports, hospitals, industrial laboratories and other key scenarios. Compared with traditional glass, ordinary plastic and common fireproof panels, it has comprehensive competitive advantages in safety performance, service life and engineering adaptability. In the future, with the continuous development of green and safe construction, this high-performance acrylic material will continue to play an irreplaceable role in modern public infrastructure construction, and become the mainstream preferred material for new and renovated public engineering projects.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction Modern public infrastructure construction prioritizes safety, visual practicality, and long-term service performance, especially for transparent decorative and protective materials used in crowded, enclosed, and&#8230;<\/p>","protected":false},"author":1,"featured_media":7664,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"Learn why UL94 V-0 flame retardant acrylic sheets are ideal for public infrastructure with fire resistance, antibacterial protection, and long-term stability.","_seopress_robots_index":"","_gspb_post_css":"#gspb_image-id-gsbp-b5abf2c img{vertical-align:top;display:inline-block;box-sizing:border-box;max-width:100%;height:auto}#gspb_image-id-gsbp-b5abf2c{margin-bottom:20px}.gs-autolist{margin:15px 0 30px;border:1px solid #dddddd7d}.gs-autolist-item{padding:15px 15px 15px 5px;display:flex;align-items:center}.gs-autolist-title,.gs-autolist-title a{font-size:18px;line-height:24px;text-decoration:none}#gspb_toc-id-gsbp-37e5a58 .gs-autolist-item{background-color:#fff}#gspb_toc-id-gsbp-37e5a58 .gs-autolist-item:nth-child(2n){background-color:#eee}#gspb_toc-id-gsbp-37e5a58 .gs-autolist-title a{color:#000}#gspb_toc-id-gsbp-37e5a58 .gs-autolist-number{border-radius:50%;margin:0 20px 0 15px;text-align:center;font-weight:700;background-color:#1d2088;color:#fff;height:25px;line-height:25px;width:25px;font-size:16px;min-width:25px}#gspb_toc-id-gsbp-37e5a58 .gs_sub_heading .gs-autolist-number{font-size:70%}","footnotes":""},"categories":[1],"tags":[],"class_list":{"0":"post-7662","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-blogs"},"acf":[],"_links":{"self":[{"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/posts\/7662","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/comments?post=7662"}],"version-history":[{"count":1,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/posts\/7662\/revisions"}],"predecessor-version":[{"id":7665,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/posts\/7662\/revisions\/7665"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/media\/7664"}],"wp:attachment":[{"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/media?parent=7662"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/categories?post=7662"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jrtacrylic.com\/pt\/wp-json\/wp\/v2\/tags?post=7662"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}